Gestational 2 hour GTT

Test ID: 

703180

CPT code:

82951

Synonyms:

Glucose Tolerance Test, Gestational (Fasting, One-hour, and Two-hour)

Clinical Use:

Screening and diagnosis of gestational diabetes

Test Information:

American Diabetes Association Standards of Medical Care in Diabetes recommendations:2
• Screen for undiagnosed type 2 diabetes at the first prenatal visit in those with risk factors using the standard nongestational diagnostic criteria.
• In pregnant women not known to have diabetes, screen for gestational diabetes mellitus (GDM) at 24 to 28 weeks of gestation using the Gestational Glucose Tolerance Screening and Diagnostic Test (Two-hour, ADA Recommendations).
• Screen women with GDM for persistent diabetes 6 to 12 weeks postpartum using nonpregnant OGTT criteria, hemoglobin A1c(102525), fasting plasma glucose (001818), or a 75-gram, two-hour oral glucose tolerance test (101200), two specimen WHO glucose tolerance test).2 Women diagnosed with GDM should, in subsequent pregnancies, be re-evaluated.
• Women with a history of GDM should have lifelong screening for the development of diabetes or prediabetes at least every three years.
Note: The American Diabetes Association (ADA) released recommendations that vary from the American College of Obstetrics and Gynecology (ACOG) recommendations. The ADA recommends the current (101000) simplified “one-step” for screening and diagnosis of gestational diabetes mellitus using a 75-gram, two-hour glucose tolerance test. The ACOG recommendations3 use a 100-gram, three-hour glucose tolerance test (102004).

Specimen Type:

Serum or plasma

Requested Volume: 

1 mL serum or plasma each tube

Minimum Volume: 

0.5 mL

Container Type: 

Gel-barrier tubes (3) or gray-top (sodium fluoride/potassium oxalate plasma) tubes (3)

Patient Preparation: 

Patient should be active and eat a regular diet that includes at least 150 grams of carbohydrate daily for three days prior to the test. The patient should be instructed not to eat or drink anything except water for at least eight hours and not more than 14 hours before the test. Patients should also be advised to discontinue, whenever possible, all nonessential medication that can affect glucose metabolism at least three days before testing.

Collection:

Draw a fasting blood sample before administering glucose. Administer a 75-gram glucose and draw blood after one hour and two hours. The patient should remain seated throughout the test. Submit 1 mL serum or plasma for fasting, one-hour, and two-hour specimens. Separate serum or plasma from cells within 45 minutes of venipuncture. Gray-top tubes only, may be submitted without centrifugation. Label each tube with the patient’s name and collection time interval (ie, fasting, one-hour, and two-hour).

Storage Instructions:

Maintain specimen at room temperature.

Stability Requirments:

Temperature

Period

Room temperature

14 days

Refrigerated

14 days

Frozen

14 days

Freeze/thaw cycles

Stable x3

Rejection Criteria

Frozen gray-top tube (frozen plasma from gray-top is acceptable); stressed patient (surgery, infection, corticosteroids) should not have GTT; specimens not labeled with collection time intervals (i.e., fasting, one-hour, and two-hour)

Return Back to Test Directory

MCI Diagnostic

Providing top patient care with fast results. 

Hours of Operation

Mon - Sat: 7 AM-11 PM

Sun: 7 AM-3 PM

COVID-19 Drive-Thru Hours

Mon-Fri: 9 AM-6 PM

Sat: 9 AM-3 PM

More Information - Click Here

Government Contract

DUNS # 125722608

Cage Code: 3FPQ3

COVID-19

COVID-19 Fee & Pricing